Doprava zdarma se Zásilkovnou nad 1 499 Kč
PPL Parcel Shop 54 Balík do ruky 74 Balíkovna 49 GLS 54 Kurýr GLS 64 PPL 99 Zásilkovna 54

Balancing Exhaust Ventilation Systems

Jazyk AngličtinaAngličtina
Kniha Brožovaná
Kniha Balancing Exhaust Ventilation Systems Vivek Balasubramanian
Libristo kód: 06820851
Nakladatelství VDM Verlag Dr. Müller, listopadu 2008
Dampers are used to adjust the distribution of §airflows in duct systems. The common (i.e., most §c... Celý popis
? points 124 b
1 242
U nakladatele na objednávku Odesíláme za 3-5 dnů

30 dní na vrácení zboží


Mohlo by vás také zajímat


Hot Vegan Robin Robertson / Brožovaná
common.buy 425
Thirteen Albatrosses DONALD HARINGTON / Brožovaná
common.buy 423
In absentia [Judici a la Terra] Jordi Ortiz / Brožovaná
common.buy 284
Industrial Power Systems Sheeba Khan / Pevná
common.buy 7 585
Sound Pulses F. G. Friedlander / Brožovaná
common.buy 1 257
Absurdist Angles on History Merritt Abrash / Brožovaná
common.buy 509
Affine Ebenen Artur Bergmann / Brožovaná
common.buy 3 581

Dampers are used to adjust the distribution of §airflows in duct systems. The common (i.e., most §commonly used) method is to adjust each damper in §turn so that the airflow through its branch equals §the desired level. Typically, the airflow through §each branch duct is estimated from the centerline §velocity pressure. To test the effectiveness of that §approach, dampers were adjusted on a seven branch, §full-sized experimental duct system. After adjusting §the dampers for a given condition, the percent §excess airflow (%Qexcess) for the system was §estimated as the amount above the ideal fan airflow §that would exist if the fan speed were adjusted so §that the lowest ratio of airflow to airflow goal for §any branch was unity. The lower the value of percent §excess airflow, the more perfectly balanced the §system was. The results varied with the level of the §target airflows. The excess airflow values were much §higher than the airflow values found by Dodrill §(2004) on the same system for the SPh Goal Ratio §method proposed by Guffey (2005). This analysis §should be useful to professionals in the fields of §HVAC and ventilation design.

Informace o knize

Plný název Balancing Exhaust Ventilation Systems
Jazyk Angličtina
Vazba Kniha - Brožovaná
Datum vydání 2009
Počet stran 72
EAN 9783639120301
Libristo kód 06820851
Nakladatelství VDM Verlag Dr. Müller
Váha 124
Rozměry 150 x 220 x 4
Darujte tuto knihu ještě dnes
Je to snadné
1 Přidejte knihu do košíku a zvolte doručit jako dárek 2 Obratem vám zašleme poukaz 3 Kniha dorazí na adresu obdarovaného

Přihlášení

Přihlaste se ke svému účtu. Ještě nemáte Libristo účet? Vytvořte si ho nyní!

 
povinné
povinné

Nemáte účet? Získejte výhody Libristo účtu!

Díky Libristo účtu budete mít vše pod kontrolou.

Vytvořit Libristo účet