Doprava zdarma se Zásilkovnou nad 1 299 Kč
PPL Parcel Shop 54 Balík do ruky 74 Balíkovna 49 GLS 54 Kurýr GLS 64 Zásilkovna 44 PPL 99

Bonding of Underground Single-Core Cables and sheath losses

Jazyk AngličtinaAngličtina
Kniha Brožovaná
Kniha Bonding of Underground Single-Core Cables and sheath losses Ossama Gouda
Libristo kód: 06947776
Nakladatelství LAP Lambert Academic Publishing, listopadu 2011
Single-core underground power cables can induce voltages and currents in their metallic sheaths. The... Celý popis
? points 149 b
1 487
U nakladatele na objednávku Odesíláme za 3-5 dnů

30 dní na vrácení zboží


Mohlo by vás také zajímat


TOP
Basic Principles of Classical Ballet Agrippina Vaganova / Brožovaná
common.buy 288
SPAD VII vs ALBATROS D III 1917-1918 Guttman Jon / Brožovaná
common.buy 362
Rainbow Body and Resurrection Francis V. Tiso / Brožovaná
common.buy 550
Simple Blessings Coloring Book Karla Dornacher / Brožovaná
common.buy 216
Olivia Audio Collection Ian Falconer / Brožovaná
common.buy 225
Psychology of Love: Popular Penguins Sigmund Freud / Brožovaná
common.buy 161
World Economic Outlook, October 2012 (Spanish) International Monetary Fund / Brožovaná
common.buy 1 733
Alien Sheep Diana Kimpton / Brožovaná
common.buy 240
Risk Layla Skinns / Brožovaná
common.buy 728
Trafficking of Persons Kimberly A. McCabe / Brožovaná
common.buy 1 464
Some Thoughts on the Incranation J Armitage Robinson / Brožovaná
common.buy 363
Determinants of Cooperative leadership in Ethiopia Muthumariappan Karthikeyan / Brožovaná
common.buy 1 648
Childhood Obesity Rexford S. Ahima / Pevná
common.buy 4 892
Modern Astrometry Jean Kovalevsky / Brožovaná
common.buy 1 542

Single-core underground power cables can induce voltages and currents in their metallic sheaths. The sheath induced currents are undesirable and generate power losses and reduce the cable ampacity whereas the induced voltages can generate electric shocks to the workers that keep the power line. This means that it is very important to know the values of sheath currents and induced voltages and the factors affecting them.So this bbbkdiscussed the following: - Calculations of the induced voltages in single-core cables with various voltages levels from 11 kV to 500 kV with briefly studying the factors affecting them. - Studying the factors affecting the sheath losses in single-core cables by calculating the sheath currents (eddy-circulating) and their sheath losses in single-core cables with various metallic sheath materials with taking into consideration the following factors: Types of sheath bonding methods (single-point bonding, two-points bonding, cross bonding) and cable layouts (trefoil, flat), cable parameters, cable spacing, sheath resistance, phase rotation, conductor current, power frequency, the minor section length in cross bonding.

Informace o knize

Plný název Bonding of Underground Single-Core Cables and sheath losses
Jazyk Angličtina
Vazba Kniha - Brožovaná
Datum vydání 2012
Počet stran 156
EAN 9783848433940
Libristo kód 06947776
Váha 224
Rozměry 150 x 220 x 8
Darujte tuto knihu ještě dnes
Je to snadné
1 Přidejte knihu do košíku a zvolte doručit jako dárek 2 Obratem vám zašleme poukaz 3 Kniha dorazí na adresu obdarovaného

Přihlášení

Přihlaste se ke svému účtu. Ještě nemáte Libristo účet? Vytvořte si ho nyní!

 
povinné
povinné

Nemáte účet? Získejte výhody Libristo účtu!

Díky Libristo účtu budete mít vše pod kontrolou.

Vytvořit Libristo účet