Doprava zdarma se Zásilkovnou nad 1 299 Kč
PPL Parcel Shop 54 Balík do ruky 74 Balíkovna 49 GLS 54 Kurýr GLS 64 Zásilkovna 44 PPL 99

Evaluation and Optimization of Sewage Treatment Plant (STP)

Jazyk AngličtinaAngličtina
Kniha Brožovaná
Kniha Evaluation and Optimization of Sewage Treatment Plant (STP) Syeda Sumaira Fatima
Libristo kód: 06936139
Nakladatelství LAP Lambert Academic Publishing, listopadu 2011
In this study, the performance of full scale domestic wastewater treatment plant was evaluated. The... Celý popis
? points 117 b
1 168
Skladem u dodavatele Odesíláme za 8-10 dnů

30 dní na vrácení zboží


Mohlo by vás také zajímat


TOP
The Montessori Baby Simone Davies / Brožovaná
common.buy 431
TOP
Batman: Hush Jeph Loeb / Brožovaná
common.buy 591
TOP
Achtung Panzer! Heinz Guderian / Brožovaná
common.buy 269
TOP
Storyfun Level 2 Home Fun Booklet Melissa Owen / Brožovaná
common.buy 345
Sun and Moon Tarot in a Tin Vanessa Decort / Karty
common.buy 408
Turn Coat Jim Butcher / Brožovaná
common.buy 283
Why Marriages Succeed or Fail John M Gottman / Brožovaná
common.buy 333
Insular Rococco Brian Earnshaw / Pevná
common.buy 1 344
The Heroes of Olympus 2: The Son of Neptune Robert Venditti / Brožovaná
common.buy 638
Computers and Games H. J. van den Herik / Brožovaná
common.buy 1 566
Translation Changes Everything Lawrence Venuti / Pevná
common.buy 5 031
Bernard Palissy Ernest Dupuy / Brožovaná
common.buy 865

In this study, the performance of full scale domestic wastewater treatment plant was evaluated. The regularly monitored parameters included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. The WWTP was operated and optimized at three different SRTs of 12d, 8d and 7d based on desired MLSS concentration and required performance in terms of BOD, COD and TSS. Maximum removal efficiency of these parameters was found to be at 7d SRT. A steady state modelling of plant was done by the simulation software Aquifas+. This study revealed that SRT is a very important operational parameter and its knowledge and its correct implementation by the plant operators should be mandatory.

Informace o knize

Plný název Evaluation and Optimization of Sewage Treatment Plant (STP)
Jazyk Angličtina
Vazba Kniha - Brožovaná
Datum vydání 2012
Počet stran 88
EAN 9783659263071
Libristo kód 06936139
Váha 149
Rozměry 150 x 220 x 5
Darujte tuto knihu ještě dnes
Je to snadné
1 Přidejte knihu do košíku a zvolte doručit jako dárek 2 Obratem vám zašleme poukaz 3 Kniha dorazí na adresu obdarovaného

Přihlášení

Přihlaste se ke svému účtu. Ještě nemáte Libristo účet? Vytvořte si ho nyní!

 
povinné
povinné

Nemáte účet? Získejte výhody Libristo účtu!

Díky Libristo účtu budete mít vše pod kontrolou.

Vytvořit Libristo účet